Design Criteria


Type
Requirements
Multifamily and Commercial
Design per IBC 2021
One and Two Family Dwellings
Design per IRC 2021
Seismic Zone
Residential: "A"
Multi-Family and Commercial: use Code Central
Seismic Design Parameters version 3.10
Wind Load - Exposure "C"
(3-second gust in miles per hour)
Risk Category I: 100 MPH
Risk Category II: 110 MPH
Risk Category III: 115 MPH
Risk Category IV: 120 MPH
Residential: 110 MPH
Foundation Depth
42 in. frost depth
Roof Snow Load
Minimum design roof snow load after allowed reductions
shall be 30 psf (i.e. Pf = 30 psf)
For drift / unbalanced loading: Pg = 33

International Energy Conservation Code 2021 (IECC)


Structure
Default Values
Ceilings
R - 49
Walls
R-21 or R-20 + R-5ci or R-13 + R-10ci or R-15ci
Floor over unheated space
R - 30
Crawl Space walls
R - 15 - Continuous

R - 19 - Framed
Basement walls
R - 15 - Continuous

R - 19 - Framed
Windows
U - 0.30